Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K971206

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1998-02-11

    (336 days)

    Product Code
    Regulation Number
    888.3358
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Meridian™ ST Femoral Stem and Vitalock® Solid Back Acetabular Shell with Peri-Apatite™ Coating are intended to be used in the primary uncemented reconstruction of the proximal femur and acetabulum damaged as a result of non-inflammatory joint disease, avascular necrosis or trauma.

    Device Description

    The Meridian® ST Femoral Stem and Vitalock® Solid Back Shell with Peri-Apatite™ Coating are intended to be used in the primary uncemented reconstruction of the proximal femur and acetabulum damaged as a result of non-inflammatory joint disease, avascular necrosis or trauma. These devices are identical to the Meridian® ST femoral stem and Vitalock® Solid Back shell previously released under K94507, K930223, and K952397 respectively, except for a thin layer of hydroxyapatite coating applied to the porous coated surface.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the Meridian® ST Femoral Stem and Vitalock® Solid Back Shell with Peri-Apatite™ Coating. This document focuses on establishing substantial equivalence to previously marketed devices rather than presenting detailed performance studies with acceptance criteria in the way one might find for a new diagnostic or AI-powered device.

    Therefore, the requested information regarding acceptance criteria, study details, sample sizes, ground truth establishment, and expert involvement is not available in the provided text. The submission primarily relies on comparing the new device's intended use, materials, design, and operational principles to existing predicate devices.

    Here's what the document does state about the assessment:

    • Equivalence Basis: "This equivalence is based upon similarities in intended use, material, design, and operational principles to the legally marketed devices."
    • Specific Testing Mentioned: "Testing to characterize the Peri-Apatite™ coating was presented, along with the results of an animal study."
    • FDA's Determination and Limitations: The FDA's letter states, "The data presented support equivalence with no additional claims over a conventional press-fit hip prosthesis (i.e., mechanical interlock, only)." It explicitly prohibits claims for "biological attachment, enhanced clinical or radiographic performance, enhanced fixation and/or long-term stable fixation." This indicates that while some testing was done (coating characterization, animal study), it was not sufficient to support efficacy claims beyond mechanical interlock, thus not meeting higher 'acceptance criteria' for biological performance.

    Conclusion:

    The provided text does not contain the specific information required to complete the table and answer the questions regarding acceptance criteria, study design, sample sizes, ground truth, experts, or MRMC studies. The 510(k) submission process outlined here is for demonstrating substantial equivalence based on fundamental device characteristics and existing predicate claims, not necessarily for proving novel performance metrics against pre-defined acceptance criteria in the manner an AI or diagnostic device would.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1